1 Sansom Institute, University of South Australia, Adelaide, SA, Australia;
2 Pediatrix Screening, Bridgeville, PA, USA;
3 Sigma-Tau Pharmaceuticals Inc., Gaithersburg, MD, USA
Corresponding author: Prof Allan M Evans. Email: allan.evans{at}unisa.edu.au
| Abstract |
|---|
|
|
|---|
Methods: Blood samples were collected from 60 healthy subjects of both genders and various ages. Plasma samples were analysed for endogenous carnitine concentrations by radioenzymatic assay, high-performance liquid chromatography and electrospray tandem mass spectrometry.
Results: Precision and accuracy of results obtained for each assay were within acceptable limits. Average endogenous concentrations obtained from the three analytical methods in this study were in the range of 38–44, 6–7 and 49–50 µmol/L for L-carnitine, acetyl-L-carnitine and total carnitine, respectively. Comparison of results between the genders indicated that males had significantly higher endogenous plasma L-carnitine and total carnitine concentrations than females. Age was found to have no impact on plasma carnitine concentrations.
Conclusion: These results are useful in the evaluation of biochemical or metabolic disturbances and in the diagnosis and treatment of patients with carnitine deficiency.
| Introduction |
|---|
|
|
|---|
Disturbances in carnitine homeostasis have been shown to impact greatly on human health. Metabolic disorders resulting in low plasma L-carnitine concentrations are associated with cardiomyopathy, encephalopathy, muscle weakness and even early death if left untreated.6,7 The less severe, but more common, secondary carnitine deficiency may be the result of impaired renal or hepatic function, or may be induced by administration of certain therapeutic agents, such as pivampicillin and valproic acid.6,8,9 It is therefore critical to properly define normal endogenous values for L-carnitine and its esters so that these carnitine deficiency disorders may be correctly and easily diagnosed.
Analytical methods used for the measurement of plasma carnitine concentrations can be categorized as enzymatic, chromatographic and mass spectrometric assays. Enzymatic assays represent the more traditional approach and most published papers of L-carnitine pharmacology have utilized this type of assay. High-performance liquid chromatography (HPLC) potentially has a wider application as it allows for the quantification of specific short-chain acylcarnitines, in addition to L-carnitine, which may be used as markers of metabolic diseases. Mass spectrometry methods are established in the diagnosis of metabolic disorders and have the added advantage of allowing the measurement of L-carnitine and an entire range of its esters in one analytical run. These assays have been reviewed in more detail elsewhere.10
While a large number of studies have reported a range of plasma L-carnitine concentrations in healthy adults (Table 1), most of these published reports have used modifications of early enzymatic assays.11–14 With the advent of newer HPLC and mass spectrometry methods, it is not known whether utilization of these methods has affected the interpretation of normal values. Consequently, the aim of this study was to determine normal concentrations and reference intervals for a number of endogenous carnitines in the healthy adult population using three analytical approaches – radioenzymatic assay (REA), HPLC and electrospray ionisation-tandem mass spectrometry (ESI MS/MS). In addition, the impact of gender and age on endogenous carnitine concentrations was examined.
|
| Materials and methods |
|---|
|
|
|---|
Sixty healthy adult subjects were recruited for study participation and were divided into four categories according to gender and age, as outlined in Table 2. A single blood sample (20 mL) was collected via venepuncture from each subject and transferred into heparinized collection tubes. Samples were stored on ice and centrifuged within 30 minutes of collection for the separation of plasma. Plasma was divided into three aliquots for sample analysis, one each for analysis by REA, HPLC and ESI MS/MS. An additional aliquot was taken from each plasma sample and combined to form a pooled plasma sample for use as a quality control.
|
All analytical laboratories were blinded to sample identification codes.
Identical quality control samples were prepared for each of the three analytical methods and submitted for analysis with the subject samples. In order to test precision, 10 aliquots of a pooled plasma sample (QCP) were included in the sample set for each method. For assessment of accuracy, quality control samples with known concentrations were prepared with dialysed plasma and designated as QCA (L-carnitine 7.50 µmol/L, acetyl-L-carnitine 1.50 µmol/L, total carnitine 9.75 µmol/L), QCB (L-carnitine 30.0 µmol/L, acetyl-L-carnitine 6.00 µmol/L, total carnitine 39.0 µmol/L) and QCC (L-carnitine 150 µmol/L, acetyl-L-carnitine 30.0 µmol/L, total carnitine 195 µmol/L). Five aliquots of each of these quality control samples were included for analysis by each analytical method.
Plasma samples were analysed for L-carnitine (free carnitine) concentrations by the Department of Chemical Pathology, Women's and Children's Hospital, Adelaide, South Australia. Samples were analysed by REA based on the method of Cederblad and Lindstedt,15 using the reaction:
|
|
Briefly, the analytical method comprised four steps: sample preparation, incubation, separation and quantification of the product. Samples were prepared by mixing 10 µL of plasma, 90 µL of water and 20 µL of carnitine acetyltransferase (1.25 mg/mL, F Hoffman La Roche Ltd, Basel, Switzerland). To this, 70 µL of a reagent solution was added, which consisted of 14C-acetyl-CoA (0.25 mCi/2.5 mL, NEN Life Science Products Inc., Boston, MS, USA) and acetyl-CoA (Sigma-Aldrich Pty Ltd.) in a combined concentration of 43 µmol/L and 0.025 mCi/3.5 mL in a potassium phosphate buffer (0.3 mmol/L, pH 7.6) containing 1.4 mmol/L N-ethyl maleimide (Sigma-Aldrich Pty Ltd., St Louis, MO, USA).
Each sample was incubated for 60 minutes at room temperature and then separated using an ion-exchange resin (BioRad AG2-X8, 20–50 mesh chloride form, BioRad Laboratories, Hercules, CA, USA). Radiolabelled product was quantified by scintillation counting. Standard curve samples were prepared using an L-carnitine chloride solution (Sigma-Aldrich Pty Ltd) over the range of 0–200 µmol/L and were processed according to the same procedure as the subject plasma samples.
High-performance liquid chromatography
Plasma samples were quantified for L-carnitine, acetyl-L-carnitine and total carnitine concentrations by the Centre for Pharmaceutical Research, University of South Australia, Adelaide, South Australia. Sample analysis was carried out using the fluorometric detection method described by Longo et al.16
In short, samples were purified by solid-phase extraction (Bond Elut SAX-Isolute cartridges 100 mg/mL, Varian, Palo Alto, CA, USA) followed by derivatisation with 1-aminoanthracene (Sigma-Aldrich Chemie GmbH) with 1-3-(dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (Aldrich Chemical Company Inc., Milwaukee, WI, USA) present as a catalyst. Chromatography was carried out using a Shimadzu pump (LC-10AD), automatic injector (SIL-10AD), system controller (SCL-10A) and spectrofluorometric detector (RF-10AXL; Shimadzu Corporation, Kyoto, Japan) together with a Varian Res Elut-BD C18 analytical column (4.6 mm x 250 mm, with spherical particles of 5 µmol/L; Varian) and an Alltech column heater (Model 530, 220 V; Alltech Associates Inc., Deerfield, IL, USA). The mobile phase was run at a flow rate of 1 mL/min and consisted of 35% acetonitrile (HiPerSolv for HPLC, BDH Laboratory Supplies, Leicestershire, UK) and 65% ammonium acetate buffer (0.1 mol/L, pH 3.5). The detector wavelengths were 248 nm (excitation) and 418 nm (emission). The sample injection volume was 20 µL and run time was 20 minutes. Integration was carried out using CLASS-VP software (Version 6.10, Shimadzu Corporation).
The standard curve was constructed using samples of dialysed human plasma spiked with aqueous solutions of L-carnitine, acetyl-L-carnitine and propionyl-L-carnitine. Calibration ranges for each of the analytes were: 2.5–160 µmol/L for L-carnitine, 0.5–32 µmol/L for acetyl-L-carnitine and 3.25–208 µmol/L for total carnitine (L-carnitine + acetyl-L-carnitine + propionyl-L-carnitine).
Electrospray tandem mass spectrometry
Subject plasma samples were analysed for L-carnitine, total carnitine and an array of 31 acylcarnitines (including acetyl-L-carnitine) by Pediatrix Screening, Bridgeville, PA, USA, based on the method described by Chace et al.17 (with modifications for plasma). Four 25 µL aliquots of each plasma sample were pipetted onto the designated target areas on purpose-prepared filter paper (S&S grade 903, Schleicher & Schuell Bioscience Inc., Keene, NH, USA) and allowed to dry for two to three hours at room temperature. Once dry, the filter papers were sealed inside individual glassine envelopes (Westvaco number 10 stamp envelopes, MeadWestvaco Corporation, Glen Allen, VA, USA) and then placed in plastic-covered foil zipper pouches containing desiccant pillows. The filter papers were then shipped to Pediatrix Screening for analysis.
The analysis involved extraction of plasma from a 3/16 in. punch of filter paper using 300 µL methanol containing stable isotopically labelled internal standards over a period of 30 minutes. Samples were then derivatized with 50 µL acidified butanol for 15 minutes at 65°C to form butyl-esters of the carnitines. The derivatized carnitines were then analysed by flow injection ESI MS/MS (API-Sciex 3000, Foster City, CA, USA) with a throughput of two minutes per sample. The modified method utilized multiple deuterated internal standards, allowing for correction for any free carnitine produced during the derivatization with acidified butanol.
Calibration ranges for each of the analytes were: 0–80 µmol/L for L-carnitine, 0–50 µmol/L for acetyl-L-carnitine and 0–10 µmol/L for non-acetyl acylcarnitines.
Total acylcarnitine concentrations were determined as the sum of all 31 of the quantified acylcarnitines. Total carnitine concentrations were calculated as the sum of L-carnitine and total acylcarnitines.
Statistical comparisons were performed on Ln-transformed data using an analysis of variance with post hoc analysis (contrasts) if significance was detected. Statistical examination of the relationship between carnitine concentrations and age was conducted using linear regression. Significance was set at an
level of 0.05. WinNonlin® Professional Version 4.1 (Pharsight Corporation, Mountain View, CA, USA) was used for all statistical analyses.
Reference interval was defined as the range of values which included 95% of the healthy population. As the distribution of carnitine concentrations within the population is slightly skewed, the lower and upper limits of the reference intervals for each analyte were determined as the 2.5 and 97.5 percentiles of the data.
| Results |
|---|
|
|
|---|
The mean precision and accuracy values for L-carnitine, acetyl-L-carnitine and total carnitine were within 9% for all the analyses; the accuracy for total acylcarnitines was slightly higher for QCA (23.0%). Precision and accuracy results for each of the analytes by each analytical method are outlined in Table 3. It should be noted that the concentrations of each analyte quantified by ESI MS/MS for the high quality control samples (QCC) were outside the standard range and consequently these results were excluded in the calculation of accuracy values.
|
|
|
|
|
| Discussion |
|---|
|
|
|---|
The analytical methods employed in this study are validated techniques and are commonly used for diagnostic and/or research purposes. The precision and accuracy results obtained in this study for each of the assays were well within acceptable limits.
Comparison of carnitine concentrations obtained from each analytical method indicated that there were significant differences in the concentrations of L-carnitine and acetyl-L-carnitine quantified. However, examination of the data reveals that the average plasma concentrations are similar and in the range of 38–44 µmol/L. Analysis of samples by HPLC and ESI MS/MS resulted in average plasma concentrations which differed by only 4.8%, whereas assay by REA produced lower average concentrations than the other analytical methods (7.8% lower than ESI MS/MS and 12.2% lower than HPLC). Endogenous acetyl-L-carnitine concentrations quantified by HPLC and ESI MS/MS were approximately 6–7 µmol/L, with 3.3% difference in average concentrations between the assays. There were no significant differences in total carnitine concentrations between the methods (49–50 µmol/L, 1.4% difference). The concentrations of carnitines obtained in the present study are comparable with those previously reported in healthy adult subjects in several studies.5,18,23,26,29–31,35,36
Examination of the effect of gender on plasma carnitine concentrations indicated that concentrations of L-carnitine and total carnitine are significantly higher in adult males than females in each of the analytical methods utilized. In this study, average L-carnitine concentrations were in the range of 35–40 µmol/L for females and 41–47 µmol/L for males, whereas total carnitine concentrations were in the range of 45–47 µmol/L for females and 52–54 µmol/L for males. Similarly, Lombard et al.27 has previously demonstrated significantly higher plasma L-carnitine and total carnitine concentrations in males than in females with L-carnitine concentrations of 39.9 ± 4.9 µmol/L and 32.5 ± 5.3 µmol/L and total carnitine concentrations of 49.4 ± 7.3 µmol/L and 43.3 ± 5.5 µmol/L in males and females, respectively. Niu et al.30 also reported significantly higher concentrations of L-carnitine and total carnitine in plasma of healthy male subjects than females; however, it was also noted that acetyl-L-carnitine concentrations were significantly different between genders, a result which was not demonstrated in the present study. Differences between the genders in plasma total carnitine concentrations were also noted by Borum et al.20 Harper et al.23 also examined the effect of gender on plasma carnitine concentrations and although a significant difference was observed in L-carnitine concentrations, no differences between males and females were noted for total carnitine. The average plasma carnitine concentrations for males and females calculated in the present study are similar to those reported in the above studies.
A limited number of studies have examined the effect of age on plasma carnitine concentrations in healthy subjects. Age was found to have no impact on any of the analytes quantified in the present study, neither with significant differences between the two age groups examined, nor differences between the age groups within the genders. Similarly, no significant correlations between age and carnitine concentrations were observed. Borum et al.20 previously demonstrated a significant correlation between age and endogenous plasma total carnitine concentrations in healthy females (but not males), a result which could not be replicated in the present study.
The reference intervals calculated from the three analytical methods in this study are very similar, with significant overlap in the intervals for each of the analytes and similar interval widths (Figure 1). However, there were slight differences in the upper and lower limits of the reference intervals obtained in this study, illustrating the importance of the development of laboratory-specific reference intervals for use in the diagnosis of primary and secondary carnitine deficiencies. In doing so, gender should be taken into consideration in the determination of reference intervals for L-carnitine and total carnitine; however, age is shown to have no impact. Laboratory-specific reference intervals are expected to be similar to those obtained from our laboratories.